SP2101 OEM 腕带接地缺陷
我们购买了 5 块 StatPro SP2101 带 10 毫米公螺柱的薄型公共点垫/腕带接地线,3 米 在这 5 件产品中,有 3 件存在缺陷,并且用万用表测试时从两个腕带端口之一到接地的电气不连续。 如果没有通过将两个端口连接至接地环来检测到这一点,则可能会危及敏感的电子硬件。买家请注意并务必进行测试!
Adrienne, We apologize for your unsatisfactory experience, we have sent out the replacement product as discussed. We are waiting for the product to be returned that you have found to be defective, so that we can have them tested and see reverified. We have provided our shipping account number to you and would appreciate if you could send those back so that we can again have them tested to see where the issue is. Thank you and again, our deepest apologies.